60A MPPT Solar Panel Regulator Charge Controller 12V/24V 1000W/2000W LCD USB




Price:
$51.11

Free Shipping


Overview and Specifications:

Product Attribute
Model Number : NA

60A Solar Battery Charge Controller LCD 12V 24V Auto with USB 5V Solar Regulator High Efficiency Solar Tracking System

L60A.5

Description:

This is a three-time controller into the evening(evening)working time,an interval of rest or pause time,Dawn working time(morning light function),the user can according to their needs,set a different time.

A:time(evening working)B:time(Pause working)C:time(dawn working)

This is a compatible MPPT charge controller PWM intelligent/efficient/energy saving,he not only has efficient MPPT controller charging function to automatically track the maximum power point,10%-30% higher than the ordinary controller chargingefficiency,also has standby energy saving,more than 30% energy than ordinary controller,the standby power consumption of only 10mA-15mA.


1.Product introduction:

“T”series of an intelligent,multi-purpose solar charge controller

LCD Screen display Battery reverse discharge protection
Simple(and more time control) operation Battery reverse polarity protection
PWM charing mode+MPPT Battery under voltage protection
Parameter user can reset Overload,short-circuit protection
A key to open and close the load Automatic Temperature compensation function
A key to restore the factory setting USB 5V charge(current 1500mA/1.5A)Optional

2.Packing Including

1pcs 60A Solar Controller MPPT L60

1pcs Temperature Sensor

1pcs English User Manual

3.LCD Operating interface description :

L60

02

03

4.Parameter table:

Parameters/Model

MPPT T-10

MPPT T-20

MPPT T-30

MPPT T-40

MPPT T-60

MPPT T-80

Maximum Power Current

12A

20A

30A

40A

60A

80A

Installation Lin(mm2)

4mm2

8mm2

10mm2

12mm2

16mm2

20mm2

Installaton Line(AWG)

10#(AWG)

8#(AWG)

7#(AWG)

6#(AWG)

4#(AWG)

2#(AWG)

Weight

280g

300g

475g

500g

800g

900g

Peak power of solar cell panel (Max Wp)

130W

260W

380W

500W

800W

1000W

Battery capacity configuration

100AH

200AH

300AH

400AH

600AH

800AH

Dimensions

143*89*46(mm)

187*97*61(mm)

188*128*61(mm)

Battery float voltage

13.8V(12V system)/27.6V(24V system)

Battery (under voltage) protection

10.6V(12V system)/21.2V(24V system)

Battery(under voltage)recovery voltage

12.6V(12V system)/25.2V(24V system)

System load loss:<=13mA

Loop Buck;<=100mV

Operation Temperature :-10degC~60degC

Storage Temperature :-30degC~-70degC

Operation Temperature :<=90%,No condensation

Temperature compensation :-4mV/Cell/degC

Maximum open circuit voltage of the solar panel

18V~24V(12V system) 36V~48V(24V system)

Solar Panel maximum open circuit voltage

<=48V

Link

Click

Click

Click

Click

Click

Click

5.Installation

04

1.Ready Qi installation tools and materials,and cable.Please matching suitable cable

2.Ensure that the current desity<4A/mm2 That will help reduce the line pressure drop.check the installation site meets the relevant safety requirements,avoid damp,dusty,flammable,explosive and corrosive gases

3.Install the controller fixed to the vertical plane,see Section V mounting aperture and hole spacing.In order to ensure a good controller cooling conditions,the controller on the bottom of each reserved 10cm space

4.As shown on the right wiring sequense:load,battery,solar Battery plate is connected to the controller to be taken to ensure that the load,battery,The polarity of the solar cell panel and controller

5. Before use:external temperature sensor probe into the left of the controller temperature probe interface probe placed in similar battery temperature.(Line extensive must be build-in devices of the external temperature probe coextensive Otherwise,the controller will control parameters of the temperature compensation of the error

6.Warning:In order to prevent accidents from occurring,install:non-professionals can not be engaged in loading and unloading operations

6.Charging Problem Solution:

  1. No proper installation of solar panels cable polarity(ldquo+rdquordquo-rdquo) Removing the polarity,you can re-install the correct
  2.  
  3. More than the rated power of solar panels to reduce solar panel power does not exceed the rated power controller discharge Problem Solution
  4. Removing the load is not properly connected to the load,re-install the correct
  5. More than the rated load power to reduce load power,the controller does not exceed the rated power
  6. Instantaneous starting current is too large,the battery capacity is too small,the replacement of high-capacity batteries,button troubleshooting
  7. Wire Cable polarity loose or too square and increase retightening bold cable
  8. All keys can troubleshoot faults,press 5 seconds to restore factory settings.

7.Pictures:

L60A.6L60A.3L60A.3L60A.4L60A.1L60A.2